图片名称

PRODUCTS

+
  • 1000-2.jpg
  • 1000-1.jpg
  • 1000-3.jpg

3-15KM Eye Safe Laser Range Finder Module


Category :

Laser Rangefinder Module


LRF Series eye-safe laser ranging module is developed based on 1535nm erbium-glass laser independently developed by our company. It belongs to levelⅠeye-safe product. The product adopts monopulse ranging, the maximum range is up to 20km. Support UART(TTL_3.3V), RS232 and RS422 (Full duplex) electrical interface (One out of three), provide upper computer software, Specifies the set and communication protocol. The advantages are stable operation functions, small size and light weight.

Keyword :

3-15KM Eye Safe Laser Range Finder Module

Product Details

Items

Performance

Model

LRF4000

LRF6000

LRF8000

LRF1040S

LRF1550S

Eye-safe grade

Class1/1M

Laser wave-length

1535±5nm

Receiving diameter

 Φ52mm

Tansmitting diameter

Φ14 mm

Receiving FOV

1.88 mrad

Beam divergence

0.3±0.05 mrad

Max ranging (meter)

Building

5600  1)

5600  1)

7100  1)

10000  1)

≥20000  1)

Vehicle

4800  1)

4800  1)

6000  1)

8000  1)

≥15000  1)

Human

3200  1)

3200  1)

3800  1)

4500  1)

≥6700   1)

Drone

≥1700  1)

≥1700  1)

2000  1)

2600  1)

≥3700   1)

Min ranging

50 m

100 m

Ranging frequency

1~10 Hz

1~5 Hz

Ranging accuracy

±1 m

±2 m

Accuracy rate

≥98%

False alarm rate

≤1%

No. of multi-target detection

3(Max)

5 (Max)

Power supply voltage

DC 4.5~156V

DC 9~15 V

Standby power consumption

Low power

1 mW

≤60 mW

≤60 mW

Non-low power

≤4 W

≤4 W

≤4 W

Average power consumption

≤4 W

≤6 W

≤6 W

Peak power consumption

≤14W

Weight

75g

180g

≤330g

Dimension (L×W×H)

65×48×32 mm

≤87×60×50 mm

≤104×64×73 mm

Working temperature

-40~+65 ℃ 

Storage temperature

-55~+75 ℃

Anti-vibration

General lower limit integrity vibration test (Chinese Military Standard) 

Anti-impact

75g/6ms

Ranging logic

First and last target, multi-target ranging, range gating

Data interface

UART

UART(TTL_3.3V)/RS232/Full duplex RS422 

Reliability

MTBF ≥ 1500h 

Optical axis stability

≤0.05 mrad 

Non-parallelism 

≤0.5 mrad (between optical axis and mounting base)

Packaging and shipping

PIC

ONLINE INQUIRY

*Note: Please be sure to fill in the information accurately, and keep the communication unblocked, we will get in touch with you as soon as possible